TD172
CANISTERS LOAD CELLS
|
|
30kg to 30t
|
40t to 100t
|
|
Capacity | L1 | L2 | L3 | L4 | M1=M2 | D |
30,50,70,100,150,200,300,400kg | 120 | 101.5 | 13 | 69 | M12 | Ø85 |
0.5,0.7t | 120 | 76 | 17 | 60 | M12 | Ø56 |
1t | 120 | 76 | 17 | 60 | M16 | Ø56 |
1.5,2,3t | 140 | 76 | 26 | 60 | M24 | Ø56 |
4,5t | 170 | 76 | 35 | 70 | M30 | Ø56 |
6,7t | 190 | 76 | 40 | 70 | M36 | Ø56 |
8,10,12,15,20,25,30t | 230 | 95 | 48 | 90 | M42 | Ø75 |
40,50t | 350 | 110 | 60 | 170 | M60X4 | 64 |
70t | 400 | 130 | 70 | 190 | M72X4 | 76 |
100t | 450 | 150 | 80 | 220 | M80X6 | 85 |
200t | 580 | 170 | 100 | 280 | M120X6 | 125 |
Specifications |
Yuyao Tongda Scales Co., Ltd. NO.33,Yan Hu South Road Lizhou Street, Yuyao, China P.O.:315403 Phone:0086-574-62632031 Fax:0086-574-62632030 E-mail: info@ascells.com
|
|||
Rated output. | 2±0.1%mV/V | |||
Non-linearity | 0.03%FSO | |||
Hysteresis | 0.03%FSO | |||
Non-repeatability | 0.02%FSO | |||
Creep in 20minutes | 0.03%FSO | |||
Temperature effect span | 0.015%FSO/10℃ | |||
Temperature effect zero. | 0.026%FSO/10℃ | |||
Compensated temperature range | -10℃~40℃ | |||
Operating temperature range | -40℃~80℃ | |||
Zero balance. | ±1% | |||
Input resistance. | 385±15 Ohms | |||
Output resistance | 350±3 Ohms | |||
Safe overload. | 150% | |||
Ultimate overload. | 300% | |||
Excitation voltage | 10VDC | |||
Maximum excitation voltage | 15VDC | |||
Insulation resistance | >2000 Meg-Ohms | |||
Environmental protection | IP67 |