TD174
CANISTERS LOAD CELLS
|
|
|
|
|
Capacity | H | D | R | H1 | H2 | D1 | D2 |
0.5,1,2,3,5t | 138.5 | Ø89 | 15 | 18 | 24 | Ø30 | Ø70 |
10,20t | 138.5 | Ø89 | 15 | 18 | 24 | Ø30 | Ø70 |
30,50t | 138.5 | Ø89 | 35 | 18 | 24 | Ø46 | Ø70 |
100t | 200 | Ø120 | 50 | 43 | 33 | Ø76 | Ø105 |
200t | 270 | Ø159 | 70 | 57 | 46 | Ø108 | Ø143 |
Specifications |
Yuyao Tongda Scales Co., Ltd. NO.33,Yan Hu South Road Lizhou Street, Yuyao, China P.O.:315403 Phone:0086-574-62632031 Fax:0086-574-62632030 E-mail: info@ascells.com
|
|||
Rated output. | 1±0.1%mV/V | |||
Non-linearity | 0.03%FSO | |||
Hysteresis | 0.03%FSO | |||
Non-repeatability | 0.02%FSO | |||
Creep in 20minutes | 0.03%FSO | |||
Temperature effect span | 0.015%FSO/10℃ | |||
Temperature effect zero. | 0.026%FSO/10℃ | |||
Compensated temperature range | -10℃~40℃ | |||
Operating temperature range | -40℃~80℃ | |||
Zero balance. | ±1% | |||
Input resistance. | 385±15 Ohms | |||
Output resistance | 350±3 Ohms | |||
Safe overload. | 150% | |||
Ultimate overload. | 300% | |||
Excitation voltage | 10VDC | |||
Maximum excitation voltage | 15VDC | |||
Insulation resistance | >2000 Meg-Ohms | |||
Environmental protection | IP67 |