TD175CT
CANISTERS LOAD CELLS
|
|
|
|
Capacity | A | Ø | D | E | H | F | M | d | d1 |
5,10klb | 1.34 | 3.50 | 4.12 | 0.283 | 1.75 | 0.75 | 1/2-20 | 0.283 | 0.406 |
25,50klb | 1.60 | 4.00 | 4.75 | 0.382 | 2.12 | 0.94 | 3/4-16 | 0.343 | 0.508 |
100klb | 2.00 | 4.60 | 5.50 | 0.406 | 2.25 | 1.14 | 1 1/4-12 | 0.406 | 0.626 |
2.5,5t | Ø34 | Ø88.9 | Ø104.6 | 7.1 | 44.5 | 19.1 | M12 | Ø7.1 | Ø10.3 |
10,25t | Ø40.6 | Ø101.6 | Ø120.7 | 9.7 | 53.8 | 23.9 | M20X2 | Ø8.7 | Ø13 |
50t | Ø50.8 | Ø116.8 | Ø139.7 | 10.2 | 57.2 | 29 | M30X2 | Ø10.3 | Ø15.9 |
Specifications |
Yuyao Tongda Scales Co., Ltd. NO.33,Yan Hu South Road Lizhou Street, Yuyao, China P.O.:315403 Phone:0086-574-62632031 Fax:0086-574-62632030 E-mail: info@ascells.com
|
|||
Rated output. | 4±0.25%mV/V | |||
Non-linearity | 0.03%FSO | |||
Hysteresis | 0.03%FSO | |||
Non-repeatability | 0.02%FSO | |||
Creep in 20minutes | 0.03%FSO | |||
Temperature effect span | 0.015%FSO/10℃ | |||
Temperature effect zero. | 0.026%FSO/10℃ | |||
Compensated temperature range | -10℃~40℃ | |||
Operating temperature range | -40℃~80℃ | |||
Zero balance. | ±1% | |||
Input resistance. | 385±15 Ohms | |||
Output resistance | 350±3 Ohms | |||
Safe overload. | 150% | |||
Ultimate overload. | 300% | |||
Excitation voltage | 10VDC | |||
Maximum excitation voltage | 15VDC | |||
Insulation resistance | >2000 Meg-Ohms | |||
Environmental protection | IP67 |