Capacity |
D |
H |
C |
A |
25,50,100,250,500,1000lb |
1.00 |
0.50 |
0.40 |
1/4-28 |
2k,3klb |
1.00 |
0.75 |
0.50 |
3/8-24 |
4k,5kklb |
1.25 |
1.00 |
0.90 |
1/2-20 |
7.5k,10klb |
1.25 |
1.00 |
0.90 |
3/4-16 |
10,20,30,50,100,200,300,500kg |
25 |
12.7 |
10 |
M6 |
1000,1500kg |
25 | 19 | 12 | M8 |
2000,2500kg | 32 | 25 | 23 | M12 |
3500,4500kg | 32 | 25 | 23 | M20 |
Specifications |
Yuyao Tongda Scales Co., Ltd. NO.33,Yan Hu South Road Lizhou Street, Yuyao, China P.O.:315403 Phone:0086-574-62632031 Fax:0086-574-62632030 E-mail: info@ascells.com
|
|||
Rated output. | 2mV/V Nominal | |||
Non-linearity | 0.20%FSO | |||
Hysteresis | 0.10%FSO | |||
Non-repeatability | 0.10%FSO | |||
Creep in 20minutes | 0.10%FSO | |||
Temperature effect span | 0.05%FSO/10℃ | |||
Temperature effect zero. | 0.10%FSO/10℃ | |||
Compensated temperature range | -10℃~40℃ | |||
Operating temperature range | -40℃~80℃ | |||
Zero balance. | ±1% | |||
Input resistance. | 350 or 700 Ohms Nominal | |||
Output resistance | 350 or 700 Ohms Nominal | |||
Safe overload. | 150% | |||
Ultimate overload. | 300% | |||
Excitation voltage | 5VDC | |||
Maximum excitation voltage | 10VDC | |||
Insulation resistance | >2000 Meg-Ohms | |||
Environmental protection | IP67 |